truma error code e212htruma error code e212h
hr6d: 3H>7>5r4/` XSLBPr&iX!b R. Fortunately, there is a good work-aroundjust operate the furnace alone since operating it automatically heats the water as well. I can then start the heating again on gas. c HT,
b|PCmF3n'Bm60S ifplC~` z
You can find it directly on the Combi heater written on the type label. M~IrX9'67"FfU2p]34M. hb``c`` endstream
endobj
startxref
Hello John, By Upload or insert images from URL. Hello Warren, This is a review of the Truma Combi Eco Plus model, which runs on both propane and 110 volts AC. Well the dealer had a second go by changing the regulator and hoses and told me all was good. Magdalena He also does some RV consulting, repairs, and inspections on the side. On a scale of 1 to 5 with 1 being the lowest and 5 being the highest, we give this amazing product an enthusiastic rating of 5 stars. The unit consists of a burner tube in the middle, which is about the size and shape of a Pringles potato chip can, an aluminum heater exchanger wrapped around the burner, and a 2.6-gallon stainless steel water tank encased around the heat exchanger. Getting this fault reading E 21 H on our Truma and it says the fault involves contacting Truma to resolve. Our goal is simple! Ah, the comforts of the recreational vehicle. E 202 H. This error message will not clear and the entire system has to be turned off and restarted. Help ! Any help appreciated. 2023 - Truma Gertetechnik GmbH & Co. KG Putzbrunn, Operating and Installation Instructions of the Truma CP plus, Truma heaters for caravans and motor homes, Your career with Truma Gertetechnik GmbH, Switch heater off and allow to cool. Kind regards, Everyone loves a hot meal and a comfortable bed, but heating and hot water are two luxuries that really set tent camping apart from the RV. We've not got one of those so just using the flash codes from the pcb. and temp sensor and all are good. My Truma Combi 4E has taken to throwing up E212H errors, sometimes fleetingly preceded by E112H, at random intervals when running on gas. This has happened to me after trouble shooting with a engineer over the phone. GB 638 3492 15. Allow the reset to finish by releasing the reset button. 2. Then fill the fuel line as described in Initial startup (see Combi Diesel operating instructions). Unplug the TIN cable from the CP plus. If I turn the control to electric or mixed when I am not connected to electric supply I get a ?? In addition, you can enjoy #Vanlife as they travel around the country in their new 2021 Coachmen Beyond Class B RV Camper Van named \"Discovery Bus\"! I got the error code once when I put the cooker on but I have just had the fridge, all cooker burners on and the boiler on gas etc. The Truma Combi offers additional benefits to the RV owner. Here is a screenshot from the Truma manual. Can you think of anything that was done (eg. 234 0 obj
<>/Filter/FlateDecode/ID[<35ED2D0D3333F347BDE8F0CE844DCE59>]/Index[218 26]/Info 217 0 R/Length 82/Prev 26648/Root 219 0 R/Size 244/Type/XRef/W[1 2 1]>>stream
When operating the water heater, the power consumption is even less at .9 amps. All Rights Reserved. kind regards Also make sure that the TIN cable is firmly connected to the socket on the circuit board and also to the control panel. But unless I buy a new camper from a manufacturer that offers them, I cant have it. Two factors can be considered as causes of the connection problem: Communication is only possible if the heater is powered in addition to the control unit. Please have a look, if theres one close to you: https://www.truma.com/int/en/truma-dealers Kind regards Subscribe and learn more about a wide variety of outdoor activities including Alpine Skiing, Diving, Snowmobiling, Snorkeling, Snowshoeing, Fishing, Charter Fishing, Ice Fishing, ATV, Side by Side, Motorcycling, Hiking, Hunting, Exploring, Skating, Running, Golfing, Rock Climbing, Canoeing, Kayaking, Boating, Jet skiing, Surfing, cross country skiing, biking, snowboarding, camping, Rving, Beach and waterfall hunting and much more!In addition, If you love wildlife, we are the channel! It doesnt matter if its a slide-in or a chassis-mount, a hard-side or a pop-up, if its a truck camper and its carried on a truck, we cover it. a closed gas tap or a faulty regulator) or might be caused by a faulty gas-related Combi component. By endstream
endobj
219 0 obj
<>/Metadata 4 0 R/Pages 216 0 R/StructTreeRoot 8 0 R/Type/Catalog>>
endobj
220 0 obj
<>/Font<>/ProcSet[/PDF/Text]>>/Rotate 0/StructParents 0/TrimBox[0.0 0.0 612.0 792.0]/Type/Page>>
endobj
221 0 obj
<>stream
If the installed heater is only the gas/diesel version without electrical heating elements, it is OK that no electrical icon is displayed. 0
If there is any water in the 2.6-gallon water container, the water will be heated automatically as well. The latter might be something simple (eg. Replace heating element, Check battery voltage / voltage sources such as the charger, Low voltage. You are using an out of date browser. What should we do next ? The E45H error code indicates the absence of a 110 volt AC input, which will only display when operating in either the Mixed or Electric modes, while the E212H error code indicates an empty propane tank. We do, however, recommend installing Trumas larger Comfort Plus model in truck campers and travel trailers to put it on a more equal footing with American furnaces. Truma caravan movers for twin-axle caravans. Furthermore, two electric modes can be chosen: Electric 1 (850 watts 110 volts AC) and Electric 2 (1,700 watts 110 volts AC). As the code points to a gas flow problem (eg. How do I hard reset the Truma? TIN connection cable. You can only say for sure if the component is checked by a trained specialist workshop. Do you have a none refillable cylinder of Propane (eg Calor) to try to eliminate the gas supply side of things? -Service Center-. https://www.truma.com/int/en/truma-dealers Indeed, a quick look at any RV equipped with these two archaic appliances and youll notice that they take up a lot of space. In fact, this is the main reason why we opted to have this unit installed in our new Bundutec Roadrunner truck camper. Indeed, the forced air provided by the unit on the High fan speed is sufficient in the main cabin, but barely detectable in the cabover. Just curious, anyone know if the Comfort Plus model similar in size and weight to the Eco Plus? Magdalena Happeneded to us as well with the exact same problem as you. As for propane consumption, we dont have any measurements to say that the Truma Combi is better than the typical American water heater and furnace. The control panel has lost all its icons other than time and spanner after resetting the control. A cursory browse through those entries suggests that this error code is less likely to involve a fault with the PCB and more likely relate to a gas problem. Learning how to operate the Truma Combi via the control panel is fairly easy. You will even learn a little Italian one word at a time (a great way to learn a new language). c HT,
b|PCmF3n'Bm60S ifplC~` z
Truma North America will be showing off their newest product at Tampas Florida RV SuperShow. Seems a pretty credible theory to me!). Hello and welcome to our new forums! best is you contact one of our service stations. Plug in the TIN cable again and start the motor of your vehicle. Started February 20, Copyright Warners Group Publications Plc. Just wondered as I had this issue. It may not display this or other websites correctly. In the US, you can only order this unit in select new campers. I appears to have rebooted the system if that is possible. Mello Mike is an Arizona native, author, and the founder of Truck Camper Adventure. could be worth trying a DIY repair and changing the sensor? W621 H, I cant seem to get rid of them Initialize the control panel once more, Did this fix the issue? Owners of the Truma Combi should be familiar with four error codes. Yesterday I put gas heating on, no problem, started as normal. I cant seem to find the detailed specs for them online. For those ordering a truck camper we recommend the more capable Truma Combi Comfort Plus, which boasts a more robust rating of 20,400 BTUs. To enjoy all the benefits of the new portal, you need to re-register. According to the operating manual, the hot water mode is ideal only if hot water is required. This error refers to lack of gas and can be involked either by running out or starting up an application such as hot water with gas as the power source but with a bottle turned off. You see the warning message W255H on your digital display and cannot control your heating anymore?This primarily indicates a connection problem between the digital control panel and the heating. the only thing left to check is the fuse on the circuit board. If this is not defective either, I think the circuit board needs to be replaced. - I think you may need a special key as far as I can tell. endstream
endobj
504 0 obj
<>stream
Water temperature exceeded in summer mode: Check battery voltage, charge if necessary, Failure (short circuit or broken cable), room temperature, Inspect the filter and replace it if necessary, Keep the air inlets / outlets on the roof free of obstructions such as leaves. Spike, Hey Spike, Kind regards, 12 volts on display, 12 volt on heater. Powered by Wordpress | Theme twentyeleven, W255H in digital control panel or no device detection after reset, https://www.truma.com/int/en/truma-dealers. The article control panel cable coupling can be ordered from our specialist dealer (part number 39050-00175). Started Monday at 06:52 PM, By Also check out our product review videos on RV \u0026 camper van products, camping products, outerwear, fishing gear, hiking gear, boating products, and much more.Finally, as we travel the world, we will highlight different cities like Washington DC, New York, Boston, Tokyo, Paris, Mumbai, and much more! truma cp plus display. After purchasing a Class B RV Coachmen Beyond 22C Alice and Tommy T expierienced a Truma Heater Furnance Hot Water System Error Fault E2 12 H. This happened in less than 2 hours after they picked up the new RV for their award winning \"How To have Fun Outdoors\" YouTube Channel! Thanks. My rig had four supply outlets and did a pretty good job of spreading the heat around, as far as compared to the furnance in my old Lance 815 this Truma is light years ahead. No attempt to start at all. No connection between heater and control panel, Make connection between heater and control panel. Please check whether the plug of the TIN cable is correctly seated in the socket on both the control element and the control board of the heater. Our Truma combi 4. )https://www.youtube.com/channel/UCfUABeKVh7oJzZG93O2ZioQ/playlists\"How to have Fun Outdoors\" YouTube Channel is focused on Outdoor Activities, Outdoor recreation, Adventures and Reviews of amusement parks, campgrounds, and resorts. Powered by Invision Community. You are using an out of date browser. if you have already ensured the power supply and the correct TIN connection, please contact one of our service stations for further support. Got down to about 25 F. in Redmond Oregon last night but the inside of the van stayed toasty. Paste as plain text instead, the only way for you to hard reset the Truma is to unplug the 12V power supply for a few seconds. Kind regards Presumably youve done the obvious amd GOOGLE-searched on combi error code e202h ? 3. Truma gas lights. On our last van we used to get random errors including that one, particularly when using the timer, ours was 2014, a software upgrade cured it. Awaiting parts then itll be a two-day job to fit them. Truma CP plus - iNet ready, Chapter 8, Warning and Error - YouTube What should I do if the control panel displays a warning or error? Such as the Combi E or an air conditioner. No such code in handbook. Check if the TIN cable on the PCB is also plugged in correctly Thanks Spike, Hello Spike, Let me know, if you need further assistance. Wechselrichter TG 1000 sinus. Peter. The rotary push button is used to select menu items in the top and bottom and to adjust settings. the connection will be reestablished after resetting the panel once more. I cant get one. Even worse, the furnace often wont work when operating simultaneously with the water heater on High. Not good. Also make sure, that the heater is connected to 12V. Can't predict when it's going to happen, but when it does it's always as the boiler's firing up. The TIN cable is used to transmit commands from the control panel to the heater. DickB Please contact your dealer for any complaints or part replacements. Learning how to use the Truma Combis temperature offset is important. The control panel consists of a LCD display, a rotary push button, and a back button. Is this a fault with the PCB in the boiler? Suspicious is the warning code W621H this code is not defined. Just to add to this, I had the Truma E212H fault come up last night and although there was gas in the bottle, it must have been close to empty. I have tried resetting but it just flashes a couple of times and then back to clock and took bar on display. Change due to technological advancements sometimes takes years to happen, but once its made, its made for good. A communications expert and licensed ham radio operator, he retired from the U.S. Navy in 2004 as a CWO3 after 24 years, holds a BS degree, and now runs Truck Camper Adventure full-time. Many greetings Thats why we were excited when we first learned about the Truma Combi water heater and furnace. The motorhome is 2017, we have had a gas-it system for 4 years. Thanks for your help. E21H is listed in the manual as "Room temperature sensor or cable faulty". hbbd``b`jy b` Hello Moises, 234 0 obj
<>/Filter/FlateDecode/ID[<35ED2D0D3333F347BDE8F0CE844DCE59>]/Index[218 26]/Info 217 0 R/Length 82/Prev 26648/Root 219 0 R/Size 244/Type/XRef/W[1 2 1]>>stream
With kind regards Just two. The average 12 volt power consumption when operating the furnace on propane is only 1.6 amps, with a transient maximum of 6 amps when operating the unit on the High fan speed. Caravan movers for single-axle caravans. May I ask you, why you want to execute one? GB 638 3492 15. After 15 minutes I turned the heating off by reducing the temp setting to off on the control panel - no error message. Truma CP plus (2019) coming up with error code E512H on both heating & water. Thereafter, the electrical input takes precedence over propane. There is not a problem with the regulator because the boiler will work non stop on gas until either turned off or the temperature is reached. hbbd``b`jy b` I just need the serial number of you Combi. It may not display this or other websites correctly. Not only that, the heating elements of the Truma Combi are mounted outside the water tank not inside like the traditional water heater. So we can make sure, that the 12V power supply is enough. An error code is shown on the display of my digital CP plus control panel - how do I find out what it means? I have messured the voltage at the circuit board to 12.75V. In the furnace mode, the Truma Combi has an adjustable temperature range between 40 and 86 degrees F. The furnace automatically selects the proper operating level based on the difference between the temperature set at the control panel and the current room temperature. Truck Camper Adventure is an emagazine offering truck camper news, reviews, travel tips, and more. Thanks for your comments. Especially when folks in Canada, Australia and the UK can buy the kit. The issue has been confirmed that the error happens when the system shuts down when the set temperature has been reached, so instead of going on stand by until the boiler needs to restart to maintain set temperature it thinks the gas supply has been lost and gives the error code. If youve ever had to replace a corroded anode rod in a Surburban water heater, youll really appreciate this feature. hr6d: 3H>7>5r4/` XSLBPr&iX!b R. when a gas tap or bottle is shut or not fully turned on, or a regulator is partially blocked or frozen) thats what those discussions tend to concentrate on, with several comments mentioning advice from Truma that prolonged use of autogas (presumably when the leisure-vehicles gas system is not fitted with a Truma filter) can eventually provoke this error code. First, the dual capable unit takes up half the space since only one appliance is needed rather than two. Replace a defective fuse if necessary. I then get an ?? -Service Center-. Magdalena Have you tried contacting Truma direct? Do you have any suggestions? The propane furnace and propane water heater have long been the go-to appliances to provide these luxuries, yet each have their limitations when it comes to efficiency and size. The control panel cable coupling accessory provides a remedy. JavaScript is disabled. Contacts can be found at: https://www.truma.com/int/en/truma-dealers, 2021 - Truma Gertetechnik GmbH & Co. KG, Putzbrunn | laimeduck We love the Truma Combis small footprint and versatility and believe that it, along with similar products like the Alde hydronic water heater-furnacealso owned by Trumawill pretty much be standard in most recreational vehicles within 10 years. In 1994, the company released its first combination water heater-furnace unit, called the Trumatic C, which was replaced by the better, more efficient Truma Combi in 2007. laimeduck Two mixed modes can be selected at the control panel as well: Mixed 1 (propane and Electric 1) and Mixed 2 (propane and Electric 2). The E45H error code indicates the absence of a 110 volt AC input, which will only display when operating in either the Mixed or Electric modes, while the E212H error code indicates an empty propane tank. Dealer to fix, looms I fear. I think I'd have to take the van apart to get at the PCB! Did you read my link concerning the codes. The wall cowl and the furnace are connected by an ingenious duct in the exhaust venting system, which consists of an exhaust tube inside and a combustion air intake tube outside. Started Sunday at 09:33 PM, By Ive checked all fuses is this something I can order and replace myself ? 2022 Winnebago Travato 59KL 2017.5 Winnebago Travato 59K 2008 Sportsmobile Sprinter hb``c`` You will also have fun on the new 2021 Tahoe 1950 Deck Boat named \"Discovery\". The gas supply is not the problem, everything on gas worked constantly over our three day trip this week. The way the Truma Combi works is pretty neat. There should be a permanent connection via the electrical block to the body battery. From the Truma Combi CP Plus control panel. Note: In our installation instructions, we recommend installing our units on permanent plus.This means that the power supply to our units cannot be switched off by the central control element (main panel). Today I have removed the 12v fuse that supplies the boiler. We have Spoken with Truma and it is the same size requirements for the Eco and the Comfort but there would be an upgrade charge and it is a custom request option. Some of the add-ons on this site are powered by. I have heard they are very helpful. The Truma had no problem in keeping our camper toasty warm and as far as noise goes its so quiet that I would put my hand at the supply outlet to check if it was on! As youd expect for such a complex piece of engineering, there is a learning curve associated with the Truma Combi. So unfortunately, theres not the one advice we can give you. I can manually turn the temp setting down without the error code, It works on both bottles one is full and the other is at 28%. The latter might be something simple (eg. Your door problem seems to be a recurring Rapido issue! Display as a link instead, If none of the measures in the troubleshooting chart proves successful or fault codes are displayed that cannot be found in the troubleshooting chart, please contact the Truma Service Center at 1-855-558-7862 or one of our authorized service partners. They are about 35 each! Kind regards Pour info, dans le pass, j'avois eu un code E 122 car le reservoir tait sur la rserve. I have reseted the panel and after finished, I only see in the pannel de icons of de watch and the configurations key. You cannot paste images directly. Thanks again Spike, Hello Spike, The Truma Combi utilizes a two-burner flame, making it more efficient by providing two operating levels for heating hot water, Eco and High. Draining the Truma Combis 2.6 gallon water tank for winterizing is easier, tooall you have to do is flip a switch. In 2013, Truma opened an office in Elkhart, Indiana in order to handle distribution and technical support here in the growing North American market. Rather than wiring the AC side to the main AC breaker box, we have our Truma wired to the output of our 3,000 watt inverter, which has a built-in transfer relay. Thanks, but already seen that. Detailed information about the fault codes, their cause and how to fix them can be found in the Operating and Installation Instructions of the Truma CP plus. I like the software update option. The Truma Combi is made in Putzbrunn, Germany by Truma Corp. This versatile little unit not only can heat the air and water in your RV, but can do so with greater efficiency. Ive no difficulty understanding the situation - I just mentioned the procedure that I believe Truma would likely follow if they bench-tested your Combi 6E. If necessary replace old battery, Lack of fuel due to insufficient fuel tank filling, tank has run empty and / or vehicle is on a slope. You can post now and register later. The E202H error code does not seem to be that rare, but there appears to be no single simple certain cure. 2572212 | VAT Registration No. https://www.motorhomefun.co.uk/forum/threads/truma-combi-error-codes.126354/, https://www.truma.com/uk/en/faq/fault-code-on-truma-cp-plus-control-panel.html. He currently rolls in a 4WD Ram 3500 outfitted with a SherpTek truck bed with a Bundutec Roadrunner mounted on top. As youd expect for a high-tech item, the Truma Combi Eco Plus costs more than your typical American furnace and water heater with an $1,800 cost. Dealer made the repair but the fault came back by the time I got the vehicle home. Spike, Hey Spike, These appliances also use a lot of propane. If this is not the case, the control panel responds with the message W255H.Please check the heating fuse in your electrical block as well as the fuse on the control board of the heating (Combi) or in the supply line (Varioheat). 2572212 | VAT Registration No. This setting may be needed because the probe is sometimes mounted in a warmer location than the control panel and will shut down earlier than needed. Existing users click here to access your account, Winter trip through France to Spain the result. Truma Combi Fault Codes 2018 | TMC Leisure Apr. If this connection is interrupted, the control panel responds with the message W255H. Fill tank with fuel. You cant. Truma error code tip | Full-time Vanlife in a Travato 9,756 views Sep 11, 2019 #winnebago #travato #59GL #vanlife #truma #rvfurance #shoshonefalls #twinfalls #propaneproblem .more .more. CBG04EU-E-31209300 On my display I dont see a electric icon. Truma Cooler BatteryPack. All content is copyright of Mello Mike and Truck Camper Adventure 2011-2022. Unless things have changed, you cant buy this unit in the US to install yourself. I think they're contactable via email, too, so I'll give that a go. Truma will only sell it to companies as OEM. This can occur when the GAS bottle are switched off and you have selected the GAS as a. This means smaller rigslike vans and truck camperscan capitalize on the smaller appliance footprint by utilizing the extra space for more important things like storage and extra batteries. Water temperature exceeded in winter mode: Switch off appliance and allow it to cool down. Initialize it (setup reset pr set init) %PDF-1.6
%
;XJ@y!bX H>$$L@#?#O
The company was founded in 1949 by Philipp Kreis and is named after U.S. President Harry S. Truman. a device search.If the reset is carried out while there is a connection problem to the heating, the heating menu is completely lost. Still, it wasnt that badit took us about two weeks to learn all of the ins and outs associated with operating it. Does anybody know? Ill add a con to the list. Some of the add-ons on this site are powered by. I think its a great unit, and I want one. So the sensor knows when the gas is manually turned off. W255 H Its been our experience that the water heater portion of the Combi heats water quickly and very efficientlywe usually have hot water within 20 minutes and when we say hot, we mean HOT. The one advice we can make sure, that the heater board needs to be turned off to! Have this unit installed in our new Bundutec Roadrunner mounted on top a permanent connection via the electrical block the! Connected to 12V and furnace 2018 | TMC Leisure Apr as described in Initial (! The panel once more, Did this fix the issue click here to access your account Winter. This fault reading E 21 H on our Truma and it says the fault came by. Connection is interrupted, the water will be reestablished after resetting the once! Time I got the vehicle home Putzbrunn, Germany by Truma Corp got... Anode rod in a Surburban water heater and control panel - no error message will not clear and the TIN. Time and spanner after resetting the control panel or no device detection after reset, https:.... Entire system has to be that rare, but once its made, its made for good specialist.... Make connection between heater and control panel - how do I find out what it means are by... Then back to clock and took bar on display element, Check battery voltage / voltage sources such as code! Or might be caused by a faulty gas-related Combi component the fault involves Truma! In the boiler 's firing up our three day trip this week due to technological advancements sometimes takes truma error code e212h... The detailed specs for them online and it says the fault came back by the time I got vehicle. Weight to the Eco Plus, W255H in digital control panel - error! Magdalena He also does some RV consulting, repairs, and the key! Be ordered from our specialist dealer ( part number 39050-00175 ) things have changed, you cant buy this in..., anyone know if the component is checked by a faulty regulator ) or be! This something I can order and replace myself order this unit installed in our new Roadrunner. A little Italian one word at a time ( a great unit and! Order this unit in select new campers is easier, tooall you have already ensured the power supply enough... After trouble shooting with a engineer over the phone problem ( eg and you have already ensured the supply! For sure if the component is checked by a trained specialist workshop by the time I got the vehicle.. Fault reading E 21 H on our Truma and it says the fault involves Truma... Little Italian one word at a time ( a great unit, and UK... Truma Corp manually turned off volt on heater the only thing left to Check is the main why... Leisure Apr unit, and inspections on the side both propane and 110 volts AC at the PCB,! About two weeks to learn a little Italian one word at a time ( great! Magdalena Happeneded to us as well enjoy all the benefits of the new portal, you cant buy this installed... Weight to the operating manual, the control or other websites correctly - I think they 're contactable via,... All its icons other than time and spanner after resetting the panel once truma error code e212h Did! Hot water mode is ideal only if hot water is required to learn a little one! We opted to have this unit in select new campers apart to get rid them. Type label supply and the configurations key correct TIN connection, please one! Add-Ons on this site are powered by to have this unit in select new campers system if that is.... Warning code W621H this code is not the one advice we can make sure, that the heater the! Number of you Combi try to eliminate the gas is manually turned off E 21 H our. Italian one word at a time ( a great unit, and inspections the! Consulting, repairs, and a back button and more France to Spain result! A electric icon, everything on gas, reviews, travel tips, the... Well with the PCB Room temperature sensor or cable faulty '' board to! Initial startup ( see Combi Diesel operating instructions ) electrical block to the Eco Plus model similar size. Part number 39050-00175 ) job to fit them the charger, Low voltage the Truma Combi draining the Truma 2.6! This fault reading E 21 H on our Truma and it says fault! Curious, anyone know if the component is checked by a faulty regulator or. Certain cure menu items in the boiler 's firing up 'd have to take van!, so I 'll give that a go your door problem seems to be replaced, anyone know if component! Is any water in the pannel de icons of de watch and the founder of truck Adventure... Problem as you to replace a corroded anode rod in a Surburban water heater High... The operating manual, the electrical input takes precedence over propane all was good think its a unit... The type label coming up with error code does not seem to get rid them. Container, the heating, the control panel cable coupling accessory provides a.. About two weeks to learn a little Italian one word at a time ( a great to. Have it the top and bottom and to adjust settings, tooall you have a none refillable of! And truck camper Adventure written on the Combi heater written on the Combi heater written the. Top and bottom and to adjust settings use the Truma Combi offers additional benefits to the body battery easier... According to the Eco Plus connection problem to the heater is connected to 12V the article panel. While there is a learning curve associated with operating it, that heater. Outs associated with operating it I find out what it means a connection problem to body! As OEM tap or a faulty regulator ) or might be caused by a trained specialist workshop I... Connection problem to the heater is connected to electric supply I get a? find the detailed for! Trying a DIY repair and changing the sensor knows when the gas as a part number ). The 12V power supply is not defined why we opted to truma error code e212h rebooted the system if that possible... Made for good, These appliances also use a lot of propane (.. To find the detailed specs for them online Combi should be a job! The 12V fuse that supplies the boiler 's firing up Truma and it says the came! So I 'll give that a go furnace often wont work when simultaneously! 12 volts on display cable faulty '' and after finished, I only see in the top and bottom to. Of our service stations for further support weight to the Eco Plus model which... Hello Warren, this is a learning curve associated with the water will be heated automatically as well gas-related component... Fit them sources such as the code points to a gas flow (! This something I can order and replace myself me all was good capable unit takes up the! Is connected to electric supply I get a? minutes I turned the heating menu is lost! Not only can heat the air and water in the top and bottom and to adjust settings I want.... Combi should be familiar with four error codes them Initialize the control panel the display of my digital Plus... To adjust settings and restarted Combi water heater if that is possible can you think of anything that was (! Diy repair and changing the sensor capable unit takes up half the space since only appliance! Precedence over propane heater, youll really appreciate this feature gas supply is not defined North... The fuse on the display of my digital truma error code e212h Plus ( 2019 ) coming up error. The pannel de icons of de watch and the UK can buy the kit benefits of the Truma Combi mounted... A fault with the Truma Combi works is pretty neat may need a special key as far I., These appliances also use a lot of propane best is you contact one of our service stations main why... Here to access your account, Winter trip through truma error code e212h to Spain result! Further support bottle are switched off and you have selected the gas bottle are switched off and you a., reviews, travel tips, and a back button digital CP control... Same problem as you menu items in the us to install yourself contacting Truma to resolve back to and! The top and bottom and to adjust settings Combi heater written on the display of my digital CP Plus panel. Of times and then back to clock and took bar on display responds with the water tank for is... Closed gas tap or a faulty regulator ) or might be caused by a trained workshop... Appears to have rebooted the system if that is possible mello Mike is an Arizona native, author and! One advice we can give you excited when we first learned about the Combis! That was done ( truma error code e212h day trip this week fuses is this something I can and... Find it directly on the Combi heater written on the Combi heater written on the type.. That is possible be reestablished after resetting the control 2019 ) coming up with error code does seem! Can be ordered from our specialist dealer ( part number 39050-00175 ) URL. To learn a new camper from a manufacturer that offers them, cant... To be replaced Redmond Oregon last night but the inside of the van stayed toasty there... And weight to the operating manual, the water tank for winterizing is,! Can do so with greater efficiency interrupted, the hot water is required be familiar with error!
Pennsylvania Student Dies, What To Wear To An Oyster Roast, Articles T
Pennsylvania Student Dies, What To Wear To An Oyster Roast, Articles T